Accessories

Accessories

The smooth and safe operation of the Drum Pumps and container pumps includes a practical range of accessories. Whether for mobile use or permanently installed in a plant – with the Lutz accessories your pump becomes a perfect filling system.

Drum Adapter PP
DRUM ADAPTER PP

suitable for pump types PP-DL with an immersion tube diameter of 32 mm

Nozzle Alu
NOZZLE ALU

The Drum adapter stabilizes the Pump tube or pump in the Drum or tank opening. It prevents the pump from tipping over in the empty Drum.

Hose Connection PP Grey
HOSE CONNECTION PP GREY

The hose connector connects the delivery hoses to the Pump tube, the Double diaphragm pumps or the Nozzle. When using a Double diaphragm pump, a suitable reducing nipple must be used in addition to the hose connection

PVC SPIRAL HOSE

The Hose is suitable for aggressive and non-flammable liquids, but also for food liquids. It is made of PVC with embedded and galvanized steel wire helix (smooth inside and outside).

Maintenance Unit
MAINTENANCE UNIT

for cleaning and oiling the supply air With pressure gauge for setting the operating pressure.

BALL VALVE

The ball valve controls the supply air and therefore the speed of the Compressed air motors.

Hose Set Alkalis + Acids
HOSE SET ALKALIS + ACIDS

The hose set is suitable for aggressive and non-flammable liquids, but also for food liquids. The hose is made of PVC with embedded and galvanized steel wire helix (smooth inside and outside).

HOSE SET CONCENTRATED ALKALIS AND ACIDS

The hose set is for concentrated alkalis + acids. The set is FDA and USP Class VI compliant. The set is used for connection to the pumping station or dispensing nozzle.

Hose Set Solvent (NBR)
HOSE SET SOLVENT (NBR)

The hose set is suitable for a wide range of commercially available solvents. The hose is electrically conductive, so it can also be used in explosive environments.

HOSE SET EXPLOSIVE MEDIA

The hose set is suitable for pure chemicals and explosive liquids. The hose is electrically conductive, so it can also be used in explosive environments.

OUTLET SPOUT PP

when using the sealing plug with gas pendulum for Nozzle PP required

Brakcet
BRAKCET

The bracket relieves pressure on the discharge spout when heavy engines are used and the turnbuckle cannot be used.

BATTERY

The battery is suitable for the battery motor B1 Battery and consists of high quality Li-Ion cells.

charger 10,8 v
CHARGER 10,8 V

Charger for the Motor B1 Battery (without battery)

Monitoring module safety box
MONITORING MODULE SAFETYBOX

The perfect solution to prevent leakage is the monitoring module that detects seal leakage in advance.

charger 10,8 v
FOOT STRAINER

The foot strainer can be used for Pump tubes PP, PVDF, aluminum and stainless steel.

Emission Protection Drum Adapter PP
EMISSION PROTECTION DRUM ADAPTER PP

Prevents hazardous gases from escaping from the Drum when using a Drum pump. This protects the operator, the environment and the drive motor from hazardous gases.

Lutz Tap Valve PP
LUTZ TAP VALVE PP

For filling and transferring neutral and aggressive liquids. The liquid flow can be easily adjusted by means of a rotary closure.

Tri-Clamp Connections
TRI-CLAMP CONNECTIONS

The Tri-Clamp reducer is suitable for connection to Eccentric screw pump tube B70V - 120.1.

Pulse Generator Ring
PULSE GENERATOR RING

The pulse generator ring must be ordered additionally to match the shaft diameter of the motor.

Support Bracket
SUPPORT BRACKET

The carrying bracket with integrated pulse sensor is the perfect upgrade for your B70V-D progressive cavity pump.

Hose Clamps
HOSE CLAMPS

The hose clamp is made of stainless steel and is suitable for tying the various delivery hoses to the hose connector.

Ex-Plug
EX-PLUG

The CEE - round plugs are suitable for the rotary commutators (three-phase current) and the electric motors (alternating current) and are used in the hazardous areas or environments.

Ex Socket
EX SOCKET

The CEE - socket are suitable for the rotary commutators (three-phase current) and the electric motors (alternating current) and are used in the hazardous areas or environments.

PVC-HOSE, FABRIC REINFORCED

The Hose is suitable for aggressive and non-flammable liquids. It is made of fabric-reinforced PVC.

SPECIAL CHEMICAL HOSE PTFE

The Hose is suitable for all common media, as well as high purity products. It can be used as either pressure or suction hose and complies with FDA and USP Class VI requirements.

Drum Adapter
DRUM ADAPTER

The Drum adapter is needed to fix the pump in the barrel opening. It this prevents the pump from tipping over when the drum is empty

Installation Flange
INSTALLATION FLANGE

The mounting flange is attached to the B70V pump and a mating flange. The flange is welded directly to the Pump tube.

Outlet Bend
OUTLET BEND

The discharge elbow allows liquids to be transferred or filled directly into another container.

SUSPENSION DEVICE

The suspension device is used for safe storage of the B70 pumps. The pumps are thus protected and their utility value is increased at the same time.

Outlet Bend
OUTLET BEND

The discharge elbow allows liquids to be transferred or filled directly into another container.

SUSPENSION DEVICE

The suspension device is used for safe storage of the B70 pumps. The pumps are thus protected and their utility value is increased at the same time.

Bypass Valve
BYPASS VALVE

The bypass valve is recommended when using a closure valve.

Hub, Motor Side
HUB, MOTOR SIDE

If the motor is supplied by the customer, the hub must also be ordered in accordance with the shaft diameter.

Motor Protection Switch
MOTOR PROTECTION SWITCH

The motor protection switch is equipped with thermal and electromagnetic releases and is mounted to the Motor with the matching support bracket.

TUBE INTEGRATION

The hose connection ensures a good conductive transition between Hose and Pump tube. In potentially explosive atmospheres, the use of conductive Hoses is mandatory

DOUBLE NIPPLE STAINLESS STEEL

The double nipple is required as a connection between the Flow meter and the hose assembly.

Drum Pump Connection
DRUM PUMP CONNECTION

The drum pump connection is required to connect the Flow Meter ST 10 / SL10 to a Drum- and container pump.

Operating Unit
OPERATING UNIT

Evaluation electronics with touch screen for operating the flow meter. The operating unit is used to evaluate the pulses and shows them as quantity on the digital display

COMBINATION PLATE

The combination plate is required to be able to fix the operating unit. It can be used for wall mounting of the modules or as a heat protection plate between the base meter and the modules.

2/2 WAY SOLENOID VALVE

The 2/2 way solenoid valve seals off the air supply to Double diaphragm pump. It is controlled via the relay module.

Protective Cover
PROTECTIVE COVER

The protective cover enables and protects the modules in case of decentralized installation of the relay module and / or the operating unit.

FLANGE CONNECTION

The flange connection is required to connect the Flow Meter ST 10 / SL10 to a piping system.

THREADED CONNECTION

The threaded connector connects the Flow Meter to screw flanges or threaded fittings.

Check Valve
CHECK VALVE

The check valve prevents the fluid from flowing back in the full hose system.

Relay Module RM10
RELAY MODULE RM10

The relay module enables quantity preselection with the appropriate connecting cables.

Relay Module Ex-RM10dK (Complete Version)
RELAY MODULE EX-RM10DK (COMPLETE VERSION)

The relay module enables filling with volume preselection in the Ex area. The Ex plug-in connections according to the mini CLIX®/eXLink® system are integrated.

POWER SUPPLY UNIT NG10

The power supply unit provides the power supply for the control unit. When using a relay module, no additional power supply unit is required, as the module contains the power supply function.

Mains Cable
MAINS CABLE

The mains connection cable is used to connect the RM10 relay module / NG10 power supply unit and the Safety Box.

Connection Cable Motor Slow 1-Fold
CONNECTION CABLE MOTOR/SLOW 1-FOLD

The connection cable is used for direct connection between the relay module RM10 and the respective Motor.

CONNECTION CABLE MAIN VALVE

The connection cable is used for direct connection between the relay module RM10 / RM30 and the main valve.

Connection Cable Slow Valve
CONNECTION CABLE SLOW VALVE

The connection cable is used for direct connection between the relay module RM10 and the Slow valve.

FIlter Pressure Reducer
FILTER PRESSURE REDUCER

Filter pressure reducer with pressure gauge for setting the operating pressure.

Insertion Sleeve
INSERTION SLEEVE

The plug-in grommet is required for connection to the coupling in order to be able to connect the maintenance unit to the compressed air hose.

HOSE COUPLING

The hose coupling with hose nozzle is required for the connection to the ball valve to be able to connect the Motor with the compressed air hose.

Screw-in fitting
SCREW-IN FITTING

The screw-in fitting enables the direct connection of hoses to the pressure or suction connection of the Double diaphragm pump.

Screw-in Hose Nozzle
SCREW-IN HOSE NOZZLE

The screw-in hose nozzle enables the direct connection of hoses to the pressure or suction connection of the Double diaphragm pump.

Hose Connection
HOSE CONNECTION

The hose connector connects the delivery hoses to the discharge/suction port of the Double diaphragm pumps or the Nozzle

Reducing Nipple (Product Side)
REDUCING NIPPLE (PRODUCT SIDE)

The reducing nipple allows the connection of two different threaded sockets.

SUCTION PIPE

The suction tube is required to be able to convey or suck in highly chemical media without the outer layer being attacked as in the case of immersion of a hose.

Suction Basket
SUCTION BASKET

The suction strainer is attached to the matching suction hose. It prevents coarse impurities in the pump's flow.

Vibration Damper Set
VIBRATION DAMPER SET

Vibration damper kit provides damping of vibrations such as vibrations, shocks and shocks.

Pulse Set Electronic
PULSE SET ELECTRONIC

The pulse set records the strokes of the Double diaphragm pump and is connected directly to the pump.

DATA LINE PULSE CONNECTION

The data lead pulse connector connects the electronic pulse connector to the appropriate control unit or pulse converter

Equipotential Bonding Cable
EQUIPOTENTIAL BONDING CABLE

The equipotential bonding cable is used for the electrically conductive connection between explosion-proof pump and container has the function of earthing and equipotential bonding.

Connection Cable
CONNECTION CABLE

The connection cable is for extending the cable for the universal motors (2, or 3-wire) and the three-phase motors (4-wire).